Xantrex XFR 2800 Operating Manual page 25

Xfr 2800 watt series programmable dc power supply
Table of Contents

Advertisement

Table 1.3 Rear Panel J2 Connector Terminals and Functions
Connector
Reference
J2-1
VRMT
J2-2
IRMT
J2-3
CNTL GND
J2-4
N/C
J2-5
VPGM–
J2-6
VPGM
J2-7
IPGM–
J2-8
IPGM
J2-9
VMON–
J2-10
VMON
J2-11
IMON–
J2-12
IMON
J2-13
N/C
J2-14
S/D–
J2-15
S/D
Release 2.1
Name
Remote Output Voltage
Programming Select
Remote Output Current Limit
Programming Select
Control Ground
No connection
Voltage Program Signal Return
Output Voltage Programming
Input
Current Program Signal Return
Output Current Limit
Programming Input
Voltage Monitor Signal Return
Output Voltage Monitor
Current Monitor Signal Return
Output Current Monitor
No connection
Shutdown Signal Return (–)
S/D Input (+)
Features and Specifications
Rear Panel Connectors and Switch
Function
Selects remote output voltage
programming when jumpered to pin 3.
Selects remote output current limit
programming when jumpered to pin 3.
Control ground.
None.
Return for voltage program signal.
Input for voltage programming signals
from an analog device.
Return for current program signal.
Input for current limit programming
signals from an analog device.
Return for voltage monitor signal.
Output for output voltage monitor signal.
Return for current monitor signal.
Output for output current monitor signal.
None.
Return for shutdown signal.
Input for shutdown signal.
23

Hide quick links:

Advertisement

Table of Contents
loading