Regarding the indicator lamps (continued)
POWER/STATUS
indicator
Blinking
In
Red
2 times
Other than those above
NOTE
• When the interior portion has become overheated, for safety purposes,
the projector is automatically shut down, and the indicator lamps may also be
turned off. In such a case, disconnect the power cord, and wait at least 20 minutes.
After the projector has sufficiently cooled down, turn the power on again.
LWU650-APS/LWU530-APS
User's Manual - Operating Guide
STATUS
DETAIL
indicator
The interior portion has become heated.
Turn the power off, and allow the projector to cool
down at least 20 minutes. After the projector has
sufficiently cooled down, confirm the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
Blinking
• Does the peripheral temperature exceed 40°C?
In
Red
• Is the setting for ALTITUDE appropriate?
1 ~ 4 times
• Is the exhaust air (hot/cold) from peripheral
equipment blowing against the ventilation opening
of projector?
For details on ALTITUDE, refer to ALTITUDE of
SERVICE in the OPTION menu. If the projector is
used with a wrong setting, it may cause damage to
the projector itself or the parts inside.
Other error has occurred.
Contact your dealer or service company.
Description
103
Troubleshooting
020-001523-01 Rev. 1 (11-2018)
LIT MAN USR APS Series