Connecting power

Connect the projector to the power source.
Warning! If not avoided, the following could result in death or serious injury.
SHOCK HAZARD! A dedicated, protected ground or earth wire must be installed on the product
by Christie qualified technicians or electricians before it can be connected to power.
SHOCK HAZARD! Only use the AC power cord provided with the product or recommended by
Christie.
FIRE AND SHOCK HAZARD! Do not attempt operation unless the power cord, power socket, and
power plug meet the appropriate local rating standards.
SHOCK HAZARD! The AC power cord must be inserted into an outlet with grounding.
SHOCK HAZARD! Do not attempt operation if the AC supply is not within the specified voltage
and power range, as specified on the license label.
SHOCK HAZARD! Disconnect the product from AC before moving, servicing, cleaning, removing
components, or opening any enclosure. Inputs A and B must be removed prior to servicing.
The appliance coupler and main power supply plug must be easily accessible for disconnecting
the product from the power source.
Caution! If not avoided, the following could result in minor or moderate injury.
Only Christie qualified technicians are permitted to open product enclosures.
Install the product near an easily accessible AC receptacle.
For products containing surge suppressors, you must adhere to the installation and power
requirements.
Installation and Power Requirements
The protected earth wire must be green/yellow 12 AWG minimum.
You must use a 20A branch circuit breaker for Input A.
1. If the projector is operating, turn it off and disconnect it from AC power.
2. Loosen the threaded bolt on the ground lug on the AC receptacle on the rear of the projector.
3. Remove 15 mm of insulated covering from both ends of the protected earth wire.
4. Insert a bare end of the protected earth wire into the hole on the top of the ground lug so it is
beneath the threaded bolt.
5. Tighten the threaded bolt to 50 in-lb.
CP2208-LP Installation and Setup Manual
020-102152-03 Rev. 1 (05-2017)