Christie CP2208-LP Installation And Setup Manual page 29

Hide thumbs Also See for CP2208-LP:
Table of Contents

Advertisement

Item
Description
B
• SOFTST—(Software State) Indicates the state of the software application running on the
integrated cinema processor (ICP). During normal operation, this LED blinks. During start up, the
LED changes from off to blinking.
• OSST—(Operating System State) Indicates the state of the ICP operating system. During normal
operation, the LED is green. During start up, the LED changes from off to green.
• FMTST—(FMT FPGA State) Indicates the state of the FMT FPGA circuit. During normal operation,
the LED is green. When the power is turned on, the LED turns green immediately.
• ICPST—(ICP FPGA State) Indicates the configured state of the ICP FPGA circuit. During normal
operation, the LED is green. When the power is turned on, the LED turns green immediately.
C
• PORT B—Indicates the status of the USB port. A green LED indicates the port is active. If the
LED is not illuminated, the port is inactive.
• PORT A— Indicates the status of the USB port. A green LED indicates the port is active. If the
LED is not illuminated, the port is inactive.
D
• STBY—The LED is green when the standby power supply is active. If the LED is not illuminated,
the standby power supply has failed or the projector circuit breaker is off.
• RUN—The LED flashes green when the projector is operating normally. If the LED is not
illuminated or solid green, a communication, software, or hardware error has occurred. If the LED
is yellow, the projector cannot communicate with the touch panel controller (TPC).
• PIB—The LED is green when the projector intelligence board (PIB) is detected and operating
correctly. A red LED indicates a communication error. A flashing red LED indicates the PIB is not
installed correctly. If the LED is not illuminated, the PIB is inactive.
• ICP—The LED is green when the ICP is operating correctly. A red LED indicates a communication
issue. If the LED is not illuminated, the ICP is inactive.
• IMB—The LED is green when the integrated media block (IMB) is operating correctly. A red LED
indicates a communication issue. If the LED is not illuminated, the IMB is inactive.
E
Indicates marriage status. In full power mode, a green LED indicates that the projector is properly
married and encrypted content can be displayed. A red LED indicates marriage is broken and
encrypted content cannot be displayed.
F
Turns the projector and the lasers on and opens the douser. Press and hold the button to close the
douser, turn the lasers off, and keep the power on. We recommend that you use this button only when
the TPC is unavailable.
G
Resets the projector electronics. After restarting, the projector returns to its previous power mode.
You must turn on the light source manually.
H
Connects the projector to 3D devices.
I
Connects the projector to Christie or third-party automation equipment.
J
Connects the projector to a 10Base-T/100Base-TX Ethernet connection.
K
Connects the projector to high-definition cinema sources. The connectors can be used together to
deliver Dual Link HD-SDI following the SMPTE 372M standard.
L
Connects the projector to the building fire alarm so the light source can be shut down in the event of
a fire. If you are not using the connection, leave the factory installed jumper cable in place.
CP2208-LP Installation and Setup Manual
020-102152-03 Rev. 1 (05-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Connecting devices to the projector and establishing communication
29