Using the Command and Response Tables

The command and response table for the transmitter begins on the
command and response table for the receiver begins on
case letters are acceptable in the command field except where indicated for the audio level
(gain and attenuation) commands. Symbols throughout the table represent variables in the
command and response fields. Examples are shown throughout the tables. The ASCII to
HEX conversion table below is for use with the command and response tables.
Space

Symbol Definitions for Transmitter SIS Commands

]
= CR/LF (carriage return/line feed)
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
= Space (hard) character
E
= Escape key (hex 1B) (W can be used interchangeably with the
X!
= EDID resolution and rate
X@
= Save EDID source
X#
= Video and sync mute status
X$
= On and off status
X%
= Video bit depth
X^
= Audio gain adjustment range
X&
= Audio level adjustment range
X*
= Audio attenuation adjustment range
X(
= Audio input format
X1)
= Audio mute
X1!
= Color bars test pattern
X1@
= Transmitter name
X1#
= Link and input status
X1$
= Audio output
X1%
= Input HDCP signal
X1^
= Internal temperature
X1&
= Resolution
X1*
= EDID switch position
X1(
= Firmware version
X2)
= Optical module manufacturer
X2!
= Tx or Rx power
X2@
= Operating temp of module
X2#
= HDCP Output Status
ASCII to Hex Conversion Table
}
character)
E
character)
See the
table
on the next page.
1 = transmitter loop-through
0 = mute off
1 = video mute
0 = off (disabled)
1 = on (enabled)
0 = auto mode (default)
1 = 8-bit
00 to 24
–18 to +24 (in 1 dB steps)
00 to 18
0 = auto (default)
1 = digital (embedded DisplayPort) audio
0 = mute all
1 = mute DisplayPort
0 = off (default)
1 = 720p at 60 Hz
Up to 24 characters, alphanumeric or minus sign only. The first character must be a letter.
The last character cannot be a minus sign. No spaces are allowed, and there is no distinction
between upper and lower case.
0 = link or input not detected
1 = digital
0 = no source detected
1 = source detected with HDCP
nnnF•nnC
nnnn
xnnnn
@xxHz
Horizontal
Vertical
00 (0 hex) through 15 (F hex) (see
v.vv
Up to 16 alphanumeric characters
xx.x dBm
nnn.n
0 = no sink
1 = HDCP sink
FOX II T/R DP 4K Transmitter and Receiver • Remote Control
next
page
23. Uppercase and lower
2 = receiver output
2 = video and sync mute
2 = mute analog
2 = 1080p at 60 Hz
1 = link or input detected
2 = analog
2 = source detected no HDCP present
item D
and the table on page 15)
2 = non-HDCP sink
page. The
2 = analog audio
19