User Guide
Green Indicator
Blinking at 1 Hz
Off
Steady on
NVMe Drive Indicators
Figure 2-34 NVMe drive indicators
l
l
Issue 08 (2019-10-30)
Yellow Indicator
Blinking at 1 Hz
Steady on
Steady on
If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives
support surprise hot swap.
Table 2-10 NVMe drive indicators (VMD enabled)
Drive Active
Indicator (Green)
Off
Steady green
Blinking green at 2
Hz
Off
Off
Steady green/Off
If the VMD function is disabled, NVMe drives support only orderly hot swap.
Table 2-11 NVMe drive indicators (VMD disabled)
Activity
Indicator (Green)
Off
Copyright © Huawei Technologies Co., Ltd.
Description
The data on the secondary drive is being
rebuilt.
A member drive in the RAID array is
removed.
The drive is faulty.
Drive Fault
Description
Indicator
(Yellow)
Off
The NVMe drive cannot be detected.
Off
The NVMe drive is working properly.
Off
Data is being read from or written to the
NVMe SSD.
Blinking yellow at
The NVMe drive is being located.
2 Hz
Blinking yellow at
The data on the secondary NVMe drive is
8 Hz
being rebuilt.
Steady yellow
The NVMe drive is faulty.
Fault Indicator
Description
(Yellow)
Off
The NVMe drive cannot be detected.
2 Hardware Description