Huawei FusionServer Pro 2288H V5 User Manual page 149

Hide thumbs Also See for FusionServer Pro 2288H V5:
Table of Contents

Advertisement

FusionServer Pro 2288H V5 Server
User Guide
Figure 9-21 Querying drive information
Step 5 Write all 0s to the drive to be cleared.
Command: badblocks -swft 0 Drive letter
Example: badblocks -swft 0 /dev/sdb
Figure 9-22 Clearing data (example)
Step 6 Remove the drive.
----End
Issue 08 (2019-10-30)
l The drive letters vary with the storage media (HDD, SSD, and USB flash drive). Ensure that the
drive letter that you entered is correct.
l This operation takes time.
l If the command fails to execute, contact technical support.
After the data is cleared, do not restart or reinstall the server. Otherwise, the system will reload data to
the drives during the startup of the server.
Copyright © Huawei Technologies Co., Ltd.
9 Common Operations