Confluence Master/Slave Selection
Control mode
VF
Settings
In a stand-alone system, this parameter is set as 0
In a confluence system, the parameter is set as 1 for the Master and 2 for the Slave
With multi-function input terminal function 45, the confluence/diversion can be configured. For
detailed operation, please refer to Chapter 2 for wiring and Chapter 3 for tuning.
The difference between Master 2 and Master 3 is that the Master 3 can be configured as
confluent with other Slaves during confluence; however, the Master 2 can be configured for
stand-alone operation.
When Pr.03-13 is set as 2: Slave, at the same time, Pr.01-01 will be set as 2 and Pr.03-15 will
be set as 1 automatically.
Slave's proportion of the Master's flow
Control mode
VF
Settings
This parameter setting is required only for the Master but not needed for the Slave.
In a confluence system, this parameter value defines the Slave's portion of the Master's flow.
Example: Slave is 60L/min and Master is 40L/min, so the setting is 60/40 * 100% = 150%
For confluence of more than 2 pumps, the values for the slaves must be the same. For
example, if the total flow for a three-pump system is 200L/min, where the Master is
40L/min, then the two Slaves should be 80L/min. The setting of Parameter 03-14 should
be 160/40 = 400%
Source of frequency command
VF
Control mode
Settings
This parameter is used for EMVJ-MF01.For detailed operation; refer to Chapter 3 for tuning.
In a confluence system, if the Slave's frequency command is given through the RS485
communication, the setting value should be 1.
Limit for the Slave reverse depressurization torque
Control mode
VF
Settings
Set the torque limit of the Slave when running reversely
Slave's activation level
Control mode
VF
Settings
This parameter setting is required only for the Master but not needed for the Slave.
This parameter determines the activation level for the Slave. A 100% value corresponds to the
full flow of the Master.
FOCPG
FOCPM
0: No function
1: Master 1
2: Slave/Master 2
3: Slave/Master 3
FOCPG
FOCPM
0.0~65535.5 %
FOCPG
FOCPM
0: Digital Operation Panel
1: RS485 Communication
2~5: Reserved
FOCPG
FOCPM
0~500%
FOCPG
FOCPM
0~100%
Chapter 4 Parameter Functions
4-39
HES Series
Factory default: 0
Factory default: 100.0
Factory default: 0
Factory default: 20
Factory default: 50