Chapter 4 Parameter Functions
 When Pr00-38=1 and Pr00-39=0, Pr00-42 is disable.
Percentage of the maximum flow
Control mode
VF
Settings
 Set up this parameter to adjust the maximum rotation frequency (maximum flow rate). It is not
necessary to stop the motor drive to set up this parameter. When this parameter is set to be
100%, it corresponds to the maximum rotation frequency of Pr01-02.
Pressure Command
Control mode
VF
Settings
Percentage of Flow command
VF
Control mode
Settings
 When Pr00-44 ≠ 0, Pressure Command will not be given by the analog signal but input by
Pr00-44.
 When Pr00-45 ≠ 0, Flow Command will not be given by the analog signal but input by Pr00-45.
 Pr00-44 & Pr00-45 can be applied in an environment without input of analog signal to do simple
test.
HES Series
FOCPG FOCPM
0~100%
FOCPG FOCPM
0~400bar
FOCPG FOCPM
0~100%
4-20
Factory default : 100
Factory default : 0
Factory default: 0