Delta HES Series Instructions For Use Manual page 87

Hybrid energy saving system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

Output frequency at malfunction
Control mode
VF
Settings
Output voltage at malfunction
Control mode
VF
Settings
DC side voltage at malfunction
Control mode
VF
Settings
Output current at malfunction
Control mode
VF
Settings
IGBT temperature at malfunction
Control mode
VF
Settings
Auto-reset LvX error
Control mode
VF
Settings 0: Disable
 When this parameter is enabled and when there is RUN signal, the hybrid servo drive will
automatically restart after repowering on.
Decode the parameter protection with the password
Control mode
Settings 1~9998
Display
 Enter the password set at Pr02-21 into Pr02-22 to unlock the parameters to make
modifications.
 Write down the setting value after you set up this parameter to avoid inconveniences.
 Use Pr02-21 and Pr02-22 to prevent any unauthorized personnel to modify/ delete parameters.
 If you forget the password, input 9999 and press ENTER, then repeat inputting 9999 and
pressing ENTER to complete the decoding procedure (This procedure has to be done in 10
seconds, if you don't finish that in 10 seconds, repeat the same procedure until you finish the
procedure in 10 sec.). Once you finish this decoding process, all the parameters will be back to
the factory settings.
 When setting up a password, all the parameters will be read as 0, except Pr02-22.
Set up a parameter protection password
Control mode
Settings 1~ 9998, 10000~65535
Display
 This parameter is for setting up a password to protect parameters. When you finish setting up a
password, keypad will display 1, which means the password protection is now effective.
 Once you input the correct password into Pr02-21, the hybrid servo drive is temporarily
unlocked. To cancel the parameter protection, set Pr02-22 =0. Once the parameter protection
is cancelled, the hybrid servo drive is without password protection even after reboot.
FOCPG
FOCPM
0.00~655.35Hz
FOCPG
FOCPM
0.0~6553.5V
FOCPG
FOCPM
0.0~6553.5V
FOCPG
FOCPM
0.00~655.35Amp
FOCPG
FOCPM
0.0~6553.5
FOCPG FOCPM
1: Enable
0~3 times of entering wrong password
0: No password set or password entered successfully in Pr02-30.
1: Parameters are locked
Chapter 4 Parameter Functions
4-35
HES Series
Factory default: Read only
Factory default: Read only
Factory default: Read only
Factory default: Read only
Factory default: Read only
Factory setting: 0
Factory setting: 0
Factory setting: 0