Delta HES Series Instructions For Use Manual page 65

Hybrid energy saving system
Hide thumbs Also See for HES Series:
Table of Contents

Advertisement

 This parameter defines the contents to be displayed in the U page of the digital keypad
KPV-CE01 (as shown in the figure).
Analog output function selection
Control mode
VF
Settings
Summary of functions
Setting Value Function
0
Output frequency (Hz)
1
Frequency command (Hz)
2
Motor speed (Hz)
3
Output current (A)
4
Output voltage
5
DC BUS voltage
7: Display the actual motor speed(r 00: forward speed; - 00:
negative speed)
8: Display the estimated output torque (%) (t 0.0: positive
torque; - 0.0: negative torque) (%)
9: Display the PG feedback (G)
10: Reserved
11: Display the signal value of the analog input terminal PO
with 0~10V mapped to 0~100%
12: Display the signal value of the analog input terminal PI
with 0~10V mapped to 0~100%
13: Display the signal value of the analog input terminal PI
with -10~10V mapped to 0~100%
14: Display temperature of the heat sink in °C (t.)
15: Display temperature of the IGBT power module °C
16: The status of digital input (ON/OFF)
17: The status of digital output (ON/OFF)
18: Reserved
19: The corresponding CPU pin status of the digital input
20: The corresponding CPU pin status of the digital output
21~24: Reserved
25: Display the signal value of the analog input terminal OI
with 0~10V mapped to 0~100%
26: Display the actual pressure value (Bar)
27: Display the kWh value
28: Display the motor temperature (currently only support
KTY84)
29: Over load rate of motor drive (OL occurred when
reaching 100%)
30: Over load rate of motor with last digit A of HES (EOL1
occurred when reaching 100%)
FOCPG
FOCPM
0~20
Chapter 4 Parameter Functions
Description
The maximum frequency is 100%
The maximum frequency is 100%
600Hz is used as 100%
2.5 times of the rated current of the Hybrid Servo
Controller is used as 100%
2 times of the rated current of the Hybrid Servo
Controller is used as 100%
450V (900V) =100%
4-13
HES Series
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
Factory default: 0