03 Digital/Analog Input/Output Parameters
Multi-function input command 3 (MI3)
Multi-function input command 4 (MI4)
Multi-function input command 5 (MI5)
Control mode
VF
Settings
 When the value of this parameter is set as 44, the pressure feedback is lower than the pressure
stable region (please refer to the description of Parameter 00-26) so the flow control will be
performed. When it enters the pressure stable region, the pressure control will be performed.
 If the setting value is 45, the confluence (OFF)/diversion (ON) function will be performed. For
detailed operation, please refer to Chapter 2 for wiring and Chapter 3 for tuning.
 Please refer to the description Parameters 00-36 if the setting value is 47 and 48,
 When under the pressure control (Pr00-09=1) and the external terminal is ON, the speed
command is the flow command. It is no longer necessary to learn what the flow command is
through the calculation of PI pressure.
Digital input response time
Control mode
VF
Settings
 This parameter is used to delay and confirm the signal on the digital input terminal.
Digital input operation direction
VF
Control mode
Settings
 This parameter defines the activation level of the input signal.
 Bit 0 for the SON terminal, bit 2 for the EMG terminal, bit 3 for the RES terminal, bits 4~6
correspond to MI3~MI5, respectively.
Multi-function output 1 (Relay 1)
Control mode
VF
Multi-function Output 2 (MOI)
Control mode
VF
Multi-function Output 3 (MO2)
Control mode
VF
Settings
FOCPG
FOCPM
0: No function
44: Injection signal input
45: Confluence/Diversion signal input
46: Reserved
47: Multi-level pressure PI command 1
48: Multi-level pressure PI command 2
51: flow command
FOCPG
FOCPM
0.001~30.000 sec
FOCPG
FOCPM
0~65535
FOCPG
FOCPM
FOCPG
FOCPM
FOCPG
FOCPM
0: No function
1: Operation indication
9: Hybrid Servo Controller is ready
11: Error indication
14: MO1 software brake output
44: Displacement switch signal
45: Motor fan control signal
Chapter 4 Parameter Functions
 You can set this parameter during operation.
4-37
HES Series
Factory default: 0
Factory default: 0.005
Factory default: 0
Factory default: 11
Factory default: 0
Factory default: 0