41: Reserved
42: PG feedback error (PGF1)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG feedback slip (PGF4)
46: Reserved
47: Reserved
48: Reserved
49: External fault input (EF)
50: Emergency stop (EF1)
51: Reserved
52: Password error (PcodE)
53: Reserved
54: Communication error (cE1)
55: Communication error (cE2)
56: Communication error (cE3)
57: Communication error (cE4)
58: Communication time out (cE10)
59: PU time out (cP10)
60: Braking transistor error (bF)
61~63: Reserved
64: Safety relay Error (SRY)
65: PG card information error (PGF5)
66: Over pressure (ovP)
67: Pressure feedback fault (PfbF)
 As a fault occurs and the machine is forced shutting down, the event will be recorded. During
shutting down, the LvS is not recorded.
Low voltage level
VF
Control mode
Settings
 This parameter is used to set the LV discrimination level.
PTC action selection
Control mode
VF
Settings
 Parameter 02-08 is used to define the operation mode of the drive after the PTC is activated.
PTC level
Control mode
VF
Settings
FOCPG
FOCPM
230V Series: 160 – 220V
460V Series: 320 – 440V
I nput Volt age
02-07
FOCPG
FOCPM
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
FOCPG
FOCPM
0.0~150.0%
0.0~150.0°C
Chapter 4 Parameter Functions
30V(60V)
LV
4-33
HES Series
Factory default: 180/360
Factory default: 1
Factory default: 50.0