Chapter 3 Flow of machine AdjustmentHES Series
Shut off the power and the re-supply power for the Slave, and then set the Slave in the
speed control mode
Speed Control Mode
Setting value
of Pr. 00-09
In this case, the Master can be tuned according to the Step 3 – Step 6 described above
Confluence/Diversion Mode Adjustment
Procedure
Follow the associated descriptions in Chapter 2 to lay out the wiring.
In the diversion state, follow steps 1-8 described above to individually adjust the parameters of
each driver.
In a confluence condition, please refer to the machine adjustment procedure for the confluence
operation
Complete the above steps.
Set the Master for pressure control mode
Parameter 00-09 = 1 for pressure control mode
Pressure control mode
Setting value
of Pr. 00-09
Set the Slave for speed control mode
Parameter 00-09 = 0 for speed control mode
Speed Control Mode
Setting value
of Pr.00-09
Respectively set the master/slave multi-function input state. For the firmware version 2.03 and
above, it is necessary to set these parameters for the Slave only
Parameter 03-00~03-02 = 45 confluence/diversion signal input
Multi-function Input
Setting values
of Pr. 03-00~03-02
Through the controller, perform the entire confluence/diversion operation.
0: Speed control
1: Pressure control
0: Speed control
1: Pressure control
0: Speed control
1: Pressure control
0: No function
l45: Confluence / Diversion signal input
3-14