01 Motor Parameters
Control mode
Control mode
VF
Settings
 This parameter determines the control mode of this AC motor.
0: V/F control, the user can design the required V/F ratio. It is used for induction motors.
1: Reserved
2: Reserved
3: FOC vector control + Encoder. It is used for induction motors.
4: Reserved
5: FOC vector control + Encoder. It is used for synchronous motors.
When the control mode is FOCPM (Pr01-00=5), Pr00-06 will follow the setting at Pr01-20
<Number of poles of the synchronous motor> to modify Pr01-02<Motor's maximum operating
frequency>. Frequency = rpm*Pole/120
6: Reserved
Source of operation command
Control mode
VF
Settings
 For the operation command, press the PU button to allow the "PU" indicator to be lit. In this
case, the RUN, JOG, and STOP button are enabled.
Motor's maximum operating frequency
Control mode
VF
Settings
 Set the maximum operation frequency range of the motor. This setting is corresponding to the
maximum flow for the system.
 When the control mode is FOCPM (Pr01-00=5), Pr00-06 will follow the setting at Pr01-20
<Number of poles of the synchronous motor> to modify Pr01-02<Motor's maximum operating
frequency>. frequency = rpm*Pole/120
Motor's rated frequency
Control mode
VF
Settings
 Typically, this setting is configured according to the rated voltage and frequency listed in the
specifications on the motor's nameplate. If the motor is intended for 60Hz, set this value as
60Hz; if the motor is intended for 50Hz, set this value as 50Hz.
 The motor's rated frequency will be different as Rated speed of the synchronous motor
FOCPG FOCPM
0:V/F
1: Reserved
2: Reserved
3: FOCPG
4: Reserved
5: FOCPM
6: Reserved
FOCPG FOCPM
0: The operation command is controlled by the digital keypad
1: The operation command is controlled by the external terminals.
The STOP button on the keypad panel is disabled
2: The operation command is controlled by RS4845.
The STOP button on the keypad panel is disabled
FOCPG FOCPM
50.00~600.00Hz
FOCPG FOCPM
0.00~600.00Hz
Chapter 4 Parameter Functions
You can set this parameter during operation.
4-23
HES Series
Factory default: 5
Factory default: 1
Factory default: 166.67
Factory default: 113.33