9.3.3.3

X500 - X505 DRIVE-CLiQ interfaces

Table 9- 22
DRIVE-CLiQ interfaces X500 - X505
Pin
1
2
3
4
5
6
7
8
A
B
Connector type: RJ45 socket; blanking plate for DRIVE-CLiQ interfaces included in the scope of delivery;
blanking plate (50 pieces) order number: 6SL3066-4CA00-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION-CONNECT 500 cables is 100 m and of MOTION-
CONNECT 800 cables 50 m.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
9.3 DRIVE-CLiQ Hub Module External DME20
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Additional system components