Meaning of the LEDs on the Terminal Module TM54F

Table 9- 14
Terminal Module TM54F - description of LEDs
LED
Color
READY
-
Green
Orange
Red
Green/red
Green / Orange
or
Red / Orange
L1+, L2+,
Red
L3+
Red
Fail-safe inputs / double inputs
F_DI z
LED
LED
(input x,
x
x+1
(x+1)+,
Red
(x+1)-)
Red
LED
LED
x
Green
Green
Green
Green
Inputs x+1 (DI 1+, 3+, .. 19+) can be set individually via parameter p10040 (TM54F).
1)
p10040 (TM54F) = 0: Input x+1 is an NC contact.
p10040 (TM54F) = 1: Input x+1 is NO contact.
Factory setting: p10040 (TM54F) = 0 for all inputs x+1.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Status
Off
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
At least one fault is present in this component.
light
Note:
The LED is activated irrespective of whether the
corresponding messages have been reconfigured.
0.5 Hz
Firmware is being downloaded.
flashing light
2 Hz
Firmware download is complete. Wait for POWER ON
flashing light
Flashing
Component recognition via LED is activated (p0154).
light
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
ON
The controllable sensor power supply is functioning fault-
free.
Continuous
There is a fault in the controllable sensor power supply.
light
ON
Sensor power supply is functioning fault-free.
Continuous
There is a fault in the sensor power supply.
light
NC contact / NC contact
Continuous
Different signal states at input x and x+1
light
No signal at input x and no signal at input x+1
Continuous
NC contact / NO contact
light
Same signal states at input x and x+1
No signal at input x and a signal at input x+1
x+1
Continuous
NC contact / NC contact
light
A signal at input x and a signal at input x+1
Continuous
NC contact / NO contact
light
A signal at input x and no signal at input x+1
Additional system components
9.1 Terminal Module TM54F
Description, cause
: (z = 0..9, x = 0, 2, ..18)
1)
: (z = 0..9, x = 0, 2, ..18)
1)
: (z = 0..9, x = 0, 2, ..18)
1)
: (z = 0..9, x = 0, 2, ..18)
1)
Remedy
Remedy and
acknowledge
fault
Carry out a
POWER ON
189