Accessories
11.1
DRIVE-CLiQ cabinet bushing
11.1.1
Description
The DRIVE-CLiQ cabinet bushing is used to connect two DRIVE-CLiQ cables and can be
installed in a control cabinet wall.
At the interface outside the control cabinet, a DRIVE-CLiQ connection is established with
degree of protection IP67 according to EN 60529; however, inside the control cabinet, a
connection is created with degree of protection IP20 or IPXXB according to EN 60529. The
interface between the control cabinet wall and the DRIVE-CLiQ cabinet bushing requires
degree of protection IP54 according to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
11.1.2
Safety Information
Note
Only cables from Siemens may be used for DRIVE-CLiQ connections.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
11
233