Electrical Connection - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

S120 Combi Power Modules

3.6 Electrical connection

3.6
Electrical connection
Non-assembled MOTION-CONNECT power cables must be appropriately prepared before
being connected to the S120 Combi.
Cables without connection cables for the motor holding brake
1. Cut the cable jacket to dimension A from the table below
2. Strip the single cores U, V, W and PE and crimp on end sleeves according to DIN 46228
Cables with connection cables for the motor holding brake
1. Cut the cable jacket to 250
2. Cut the single cores U, V, W and PE to dimension A from the table below, strip and crimp
3. Strip the connection cables for the motor holding brake and screw to the brake connector
Figure 3-17
Stripped lengths for power cables
Cable cross-section in mm
4 x 1.5
4 x 2.5
4 x 4
4 x 6
4 x 10
96
on end sleeves according to DIN 46228
2
mm
± 5
A in mm and (inches)
55
(2.17
+3
55
(2.17
+3
55
(2.17
+3
55
(2.17
+2
55
(2.17
+2
)
+0.12
)
+0.12
)
+0.12
)
+0.08
)
+0.08
SINAMICS S120 Combi