9.3.7

Specifications for use with UL approval

Pre-assembled cables
Sensor/actuator cable, 5-pin, variable cable,
free cable end at straight socket M12-SPEEDCON,
cable length: 2, 5, 10, 15 m
SAC-5P-xxx-186/FS SCO
Up to 100 m on request
Phoenix Contact, www.phoenixcontact.com
Cables to be assembled by the user
Cable
Cable coil, black PUR/PVC, 5-pin
Conductor colors: brown/white/blue/black/gray
Cable length: 100 m
SAC-5P-100.0-186/0.75
Order number: 1535590
Phoenix Contact, www.phoenixcontact.com
Power supply
The DME20 must be connected to a 24 V power supply with voltage limitation.
● SITOP 6EP1x.. or 6ES7307..
● SINAMICS Control Supply Module 6SL3100-1DE22-0Axx
Pin assignment of the cable
Table 9- 24
Connection to X524 electronics power supply
1) The colors stated refer to the cable specified above
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Pin
Designation
1 (brown)
Electronics power supply
1)
2 (white)
Electronics power supply
1)
3 (black)
Electronics ground
1)
4 (blue)
Electronics ground
1)
5 (gray)
Not connected internally
1)
9.3 DRIVE-CLiQ Hub Module External DME20
Connector
Sensor/actuator connector, socket, straight, 5-pin, M12,
A-coded
Screw connection, metal knurl, cable gland Pg9
SACC-M12FS-5CON-PG9-M
Order number: 1681486
Technical specifications
The connection voltage of 20.4 V –
28.8 V refers to the (terminal)
voltage at the DME20. This must be
taken into account when selecting
the cable cross-section and supply
cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
Additional system components