Calibrating The Welder - Car-O-Liner CTR9 Instruction Manual

Spot welder
Table of Contents

Advertisement

Car-O-Liner Group AB
CTR9

4.3.1 Calibrating the welder

Calibration must always be performed at Startup and with necessary inter-
vals. To calibrate welder, push C-Tong trigger button [1] and weld without
anything between the electrodes [2].
The "Calibration" message below is shown on the Control panel display
when calibration is necessary.
To perform a correct calibration, the electrode caps must be clean and have
the right radius, see section 4.5.3 Changing the C-Tong electrode caps.
The "Caps Service" message below is shown on the Control panel display
when cleaning or changing electrode caps is necessary.