Pump Maintenance Screen 2 - Graco E-Flo iQ Operation Manual

Dispense system
Table of Contents

Advertisement

Maintenance
Press and hold the
down. The driver rod will move down as long as the soft
key is held or until it reaches the bottom.
Press and release the
rod to the bottom.
NOTE: A medium force and relatively slow speed is
used.
Press the
soft key to exit the manual pump
movement mode.

Pump Maintenance Screen 2

Use the ADM's Directional Keypad (CH) to navigate to
screen 2. This screen shows the driver calibration status
and the driver usage histogram.
A
indicates that the driver is calibrated and ready to
operate. A
indicates the driver must be calibrated
before operation.
The histogram represents how hard the driver has been
run in its lifetime. Each cycle falls between 0% and
100%. For example, five pump cycles at maximum force
would be all the way to the right at 100%. Five pump
cycles at minimum force would be all the way to the left
at 0%.
Press the
soft key to toggle between the histogram
displaying the total lifetime cycles and the cycles since
the last reset.
Press the
soft key to enter editing mode.
50
soft key to move the driver rod
soft key to move the driver
When in editing mode with the Cycles Since Last Reset
histogram showing, pressing the
right resets the histogram.
Press the
soft key to show the Driver Calibration
screen. Press the
calibration. Refer to your driver manual for calibration
instructions.
Press the
soft key to exit editing mode.
soft key on the