Graco E-Flo iQ Operation Manual page 76

Dispense system
Table of Contents

Advertisement

Integration
Automation Outputs
Instance ID
1
System Enable/Remote Start Request
2
3
4
5
6
7
8
9
10
11
12
Auto Depressurization Cancel Request
13
Acknowledge / Clear Errors (both pumps)
14
15
16
17
18
Style Fieldbus Pre-charge Request
19
20
21
22
23
42
43
44
45
46
47
48
49
76
E-Flo iQ Advance Map 18A915
Automation OUTPUTS (signal from PLC to E-Flo iQ )
Description
SYS - Data Exchange Command
System Disable Request
PLC Lockout/Control
Style Enable
Go Signal
Dispense Complete
Tandem Crossover Request
Prime Inactive Pump Request
Valve Depressurization Request
Platen Depressurization Request
Reserved Bit 1
Reserved Bit 2
Reserved Bit 3
Reserved Bit 4
Desired Active Style Number
(xxx.x bars)
Style Fieldbus Flow-rate Request
(xxxx cc/min)
Style Fieldbus Shot Size Request
(xxx.xx cc)
Prime Pressure Target (xxx.x bar)
Prime Flow Target (xxxx cc/min)
System Heat Enabled Request
System Heat Disable Request
Heat PLC Lockout/Control
Heat On Request
Heat Off Request
Heat Setback Request
Acknowledge / Clear Heat Errors
Reserved Bit 1
Data Type
Bit
uint16
0-15
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
uint16
0-15
uint16
0-15
uint16
0-15
uint16
0-15
uint16
0-15
uint16
0-15
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
Byte
Heat
0-1
2
3
4-5
6-7
8-9
10-11
12-13
14-15
16
333587B