Troubleshooting
Error
Location Type
MAD_
Pump
Advisory
MBD_
Pump
Advisory
MLC_
Pump
Advisory
MLD_
Pump
Advisory
MED_
Pump
Advisory
MG2_
Pump
Advisory
MG3_
Pump
Advisory
P1C_
Pump
Alarm or
P2C_
Deviation
(user
selectable)
P4C_
Pump
Alarm or
P3C_
Deviation
(user
selectable)
P6D_
Pump
Deviation
60
Error
Error Name
Description
Maint. Due Pump
Maintenance
P_
due for pump
Maint. Due Driver
Maintenance
P_
due for driver
Rebuild Platen
Maintenance
Seals P_
due for platen
seals
Maint. Due
Maintenance
Platen Valve P_
due for platen
valve
Maint. Due
Maintenance
Dispense Valve
due for
P_
dispense valve
Low Filter
Low filter
Pressure P_
pressure drop
detected
High Filter
High filter
Pressure P_
pressure drop
detected
Low Pressure P_
Measured
outlet pressure
less than
desired outlet
pressure minus
tolerance
High Pressure P_
Measured
outlet pressure
greater than
desired outlet
pressure plus
tolerance
Outlet Pressure
Outlet pressure
Sensor P_
transducer not
connected
Cause
Solution
The number of
Perform desired maintenance and reset the
pump cycles since
pump cycles in the setup screen.
last reset has
exceeded the
maintenance limit
set
The number of
Perform desired maintenance and reset the
driver cycles since
driver cycles in the setup screen.
last reset has
exceeded the
maintenance limit
set
The number of
Rebuild the platen seals if desired and reset
replaced drums
the platen cycles in the setup screen.
since last cycles
reset has exceeded
the maintenance
limit set
The number of
Perform desired maintenance and reset the
platen valve cycles
platen valve cycles in the setup screen.
since last reset has
exceeded the
maintenance limit
set
The number of
Perform desired maintenance and reset the
dispense valve
dispense valve cycles in the setup screen.
cycles since last
reset has exceeded
the maintenance
limit set
The filter has an
Replace the fluid filter.
opening in it
There is a clog in
Clean out the manifold to reduce the
the manifold
pressure.
Incorrect pressure
Enter correct pressure tolerance percentage
tolerance
in setup screen.
Failed pressure
Check transducer, replace if failed.
transducer
No or insufficient
Increase material flow.
material flow
Restrictor not
Slowly close restrictor to build pressure.
closed enough
Incorrect pressure
Enter correct pressure tolerance percentage
tolerance
in setup screen.
Failed pressure
Check transducer, replace if failed.
transducer
Clog in fluid supply
Check hose and other components in fluid
system
supply system for clogs.
The outlet pressure
Verify outlet pressure transducer is installed
transducer is not
and/or connected correctly. Replace if
connected or faulty
necessary.