Graco E-Flo iQ Operation Manual page 61

Dispense system
Table of Contents

Advertisement

Error
Location Type
P6V_
Pump
Alarm
P6X_
Pump
Alarm
TA__
AMZ
Alarm
T1__
AMZ
Alarm
T2J_
Driver
Deviation
T2__
AMZ
Advisory
T3J_
Driver
Deviation
T3__
AMZ
Advisory
333587B
Error
Error Name
Description
Valve Pressure
Valve pressure
Sensor P_
transducer not
connected.
Valve Pressure
Valve pressure
Sensor
transducer not
connected.
Heat Zone Offline
The heat zone
Z_H_
is offline
Low Temperature
Temperature of
H_Z_
the zone is
below the
setpoint
Motor
Motor
Temperatures
temperature
Sensor P_
thermistor
disconnected
Low Temperature
Temperature of
H_Z_
the zone is
below the
setpoint
Temperature
Current
Cutback P_
supplied to
motor is being
reduced in
order to lower
driver
temperature
High
The zone
Temperature
temperature
H_Z_
has exceeded
the setpoint
Cause
Solution
The valve pressure
Verify valve pressure transducer is installed
transducer is not
and/or connected properly. Replace if
connected to the
necessary.
driver or faulty
The valve pressure
Verify valve pressure transducer is installed
transducer is not
and/or connected properly. Replace if
connected to the
necessary.
fluid cube or faulty
The AMZ lost
Restore communication.
communication with
the other Tandem
AMZ
Zone has reached
Check resistance of heater rods. Refer to
setpoint but
manual for resistance.
dropped below
setpoint and can
not recover
Adjust the temp offset errors in the Heat
Setup screen.
The motor
Verify motor temperature thermistor is
temperature
installed and/or connected correctly. Replace
thermistor is not
if necessary.
connected or faulty
Zone has reached
Check resistance of heater rods. Refer to
setpoint but
manual for resistance.
dropped below
setpoint and can
not recover
Adjust the temp offset errors in the Heat
Setup screen.
The control board
Ensure ambient temperature is below 120F
temperature inside
(48C). Ensure the enclosure fans are
the driver is too
working properly.
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
Element continues
Defective RTD. Replace.
to raise above the
setpoint
RTD not in correct
See manual to find correct location of RTD
location on element
on element.
Temperature
Adjust the temp offset errors in the Heat
reading has risen
Setup screen.
too high.
Troubleshooting
61