Error Codes - Graco E-Flo iQ Operation Manual

Dispense system
Table of Contents

Advertisement

Error Codes

Error
Location Type
A1__
AMZ
Alarm
A2__
AMZ
Advisory
A3__
AMZ
Alarm
A4J_
Driver
Alarm
A4N_
Driver
Alarm
A4__
AMZ
Alarm
A7__
AMZ
Alarm
333587B
Error
Error Name
Description
Low Current
Heater current
H_Z_
is below the
minimum
allowed value
Low Current
Heater current
H_Z_
is below the
minimum
allowed value
High Current
Heater current
H_Z_
exceeds
maximum
allowed value
High Motor
Motor current
Current P_
exceeds
maximum
allowed value
High Motor
Motor current
Current P_
exceeds
maximum
allowed value
High Current
Heater current
H_Z_
exceeds
maximum
allowed value
Unexpected
Heat current
Current H_Z_
has an
unexpected
current flow
Cause
Solution
Fault heater
Check heater resistance and resistance to
element
ground. Replace faulty heater.
Fault heater
Check heater resistance and resistance to
element
ground. Replace faulty heater.
Heater element is
Replace heater element.
defective
Heater element is
Check wiring to the heater element to ensure
shorted
no bare wires are touching and that no wires
are shorted to ground.
Encoder
Replace encoders.
malfunction
Short circuit of
Check wiring to the motor to ensure no bare
motor wiring
wires are touching and that no wires are
shorted to ground.
Motor not able to
Check that motor shaft rotates freely.
rotate
Flow rate is too
Reduce the outlet flow rate.
large for the motor
to drive the pumps
at the operating
pressure
Encoder
Replace encoders.
malfunction
Short circuit of
Check wiring to the motor to ensure no bare
motor wiring
wires are touching and that no wires are
shorted to ground.
Motor not able to
Check that motor shaft rotates freely.
rotate
Faulty circuit board
Replace motor control circuit board.
Heater element is
Replace heater element.
defective
Heater element is
Check wiring to the heater element to ensure
shorted
no bare wires are touching and that no wires
are shorted to ground.
Unexpected
Fault heater element. Check heater
Current flow to the
resistance and resistance to ground.
heat element
Replace heater element.
Faulty AMZ; replace AMZ.