Troubleshooting
Error
Location Type
T4J_
Driver
Alarm
T4M_
Driver
Alarm
T4__
AMZ
Alarm
T6__
AMZ
Alarm
T8__
AMZ
Alarm
V1M_
Driver
Alarm
V2H_
AMZ
Deviation
V4M_
Driver
Alarm
V4H_
AMZ
Alarm
V6H_
AMZ
Alarm
62
Error
Error Name
Description
High Controls
Temperature of
Temperature P_
the control
board is too hot
High Motor
Temperature of
Temperature P_
the motor is too
hot
High
The zone
Temperature
temperature
H_Z_
has exceeded
the setpoint
Sensor Error
The zone has
H_Z_
no reading from
RTD
No Temperature
The zone
Rise H_Z_
temperature
does not
changed
Low Voltage P_
Supplied bus
voltage is below
minimum
acceptable limit
Low Voltage H_
The incoming
power is below
minimum
acceptable limit
High Voltage P_
Supplied bus
voltage is
above
maximum
acceptable limit
High Voltage H_
The incoming
power is above
minimum
acceptable limit
Wiring Error H_
The wiring is
invalided from
what the AMZ
is expecting
Cause
Solution
The control board
Ensure ambient temperature is below 120F
temperature inside
(48C).
the driver is too
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
The motor
Ensure ambient temperature is below 120F
temperature inside
(48C).
the driver is too
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
Element continues
Defective RTD. Replace.
to raise above the
setpoint
RTD not in correct
See manual to find correct location of RTD
location on element
on element.
No reading from the
Check the wired connections to make sure
RTD of the heat
that RTD is wired correctly.
zone
Defective RTD. Replace.
The zone
Check fuse on the AMZ that the error
temperature does
element is connected to.
not changed
Check that electrical connector on the
heated hose is plugged into the AMZ.
Defective heater rods in element. Replace.
Transformer faulty
Check output voltage of transformer to verify
it is within acceptable input limits.
Incorrect line
Check line voltage to verify it is as expected
voltage
(230V, 380V, etc.).
Incoming line to line
Verify incoming power is correct gauge for
voltage has
current draw and verify incoming power lines
dropped below
are securely attached to disconnect.
175V
Transformer faulty
Check output voltage of transformer to verify
it is within acceptable input limits.
Incorrect line
Check line voltage to verify it is as expected
voltage
(230V, 380V, etc.).
Incoming line to line
For 3 phase with neutral have qualified
voltage has
electrician verify neutral wire.
increased above
265V
Wrong wiring of the
Verify incoming power is wired to the
power source to the
disconnect correctly per the manual.
AMZ