Updating the Firmware

Firmware for the TLP 700 can be upgraded using the
below) or using your
and ensure that the TLP 700 has a unique IP address.

Updating Firmware Using the Extron Firmware Loader Utility

NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Web browser GUI
To use this method, you must have Extron Firmware Loader installed on your PC.
The program can be downloaded and installed, free of charge, from the Extron
Web site, following the same procedure that was used for downloading and
installing GUI Configurator and Global Configurator (see previous page).
Your PC must have internet access and be on the same network as the
TouchLink Panel.
On the Extron Web site, select the Download tab (see
Click Firmware from the options at the bottom of the page.
Click T in the alphabet menu and navigate to the TLP 700 firmware and click Download.
The TLP 700 firmware is compatible with both the TLP 700MV and TLP 700TV.
The firmware downloads to your computer.
Make a note of the folder in which the firmware file is saved.
NOTE:
Open the Extron Firmware Loader. The Add Device... dialog box opens.
Select TLP 700MV or TLP 700TV from the device list.
Select TCP/IP as the connection method.
Enter the IP address for the TLP 700, a Telnet port number, and, if necessary, the
administrator password. Click OK.
NOTES:
The factory configured passwords for all accounts on this device have been
set to the device serial number. Passwords are case sensitive.
If the device is reset to default settings, the password will be the default
password configuration. The default password is extron.
The device name appears in the connected device box with a green check mark.
Use the Browse button to locate the firmware file that you downloaded in step 3.
Click Add. The main Firmware Loader window comes into focus with the TLP 700 in
the device list.
Highlight the TLP 700 and click Begin. The firmware transfer begins and the progress is
shown by a green bar in the Total Progress panel.
When "Total Progress" shows 100% and Completed, exit the Firmware Loader.
When the firmware is installed, calibrate the panel, using the
TouchLink panel Web pages
page 12) or the
Extron Firmware Loader
(see page 19). Before starting, consult your IT team
(see page 20).
TLP 700MV and TLP 700TV • Configuration Software
(see
figure 15
on the previous page)
on-screen menus
(see
18