Extron electronics TLP Pro 300M User Manual

Extron electronics TLP Pro 300M User Manual

Touchlink pro touchpanel and scheduling panel
Hide thumbs Also See for TLP Pro 300M:

Advertisement

Quick Links

TLP Pro 300M and TLS 300M
TouchLink Pro Touchpanel and Scheduling Panel
User Guide
TLP Pro 300M and TLS 300M
68-3146-01, Rev. E
03 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLP Pro 300M and is the answer not in the manual?

Questions and answers

Summary of Contents for Extron electronics TLP Pro 300M

  • Page 1 TLP Pro 300M and TLS 300M TouchLink Pro Touchpanel and Scheduling Panel User Guide TLP Pro 300M and TLS 300M 68-3146-01, Rev. E 03 24...
  • Page 2 Safety Instructions Safety Instructions • English Instructions de sécurité • Français AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le WARNING: This symbol, , when used on the product, is intended to produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit alert the user of the presence of uninsulated dangerous voltage within the d’une tension électrique dangereuse susceptible de provoquer un choc product’s enclosure that may present a risk of electric shock.
  • Page 3 安全说明 • 简体中文 警告: 产品上的这个标志意在警告用户, 该产品机壳内有暴露的危险 电压, 有触电危险。 注意: 产品上的这个标志意在提示用户, 设备随附的用户手册中有重 要的操作和维护(维修)说明。 关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍使 用的特性等相关内容, www.extron.com 敬请访问 Extron 网站 , ,参见 Extron 安全规范指南,产品编 。 号 68-290-01 安全記事 • 繁體中文 안전 지침 • 한국어 경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는 警告: 若產品上使用此符號,...
  • Page 4 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5 Conventions Used in this Guide Notifications In this user guide, the following are used: WARNING: Potential risk of severe injury or death. AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure. ATTENTION: •...
  • Page 7: Table Of Contents

    Contents Introduction ................................1 About the TLP Pro 300M and TLS 300M ......................1 TLP Pro 300M ..............................1 TLS 300M ...............................1 Features ................................1 Both Models ..............................1 TLP Pro 300M Only ............................2 TLS 300M Only ..............................2 Application Diagram ............................4 TLP Pro 300M ..............................4 TLS 300M ...............................5...
  • Page 8 Full Factory Reset ............................35 Toggle DHCP Client .............................36 Secure Sockets Layer (SSL) Certificates ......................36 IEEE 802.1X Certificates ..........................37 Certificate File Requirements ........................37 Private Key File Requirements ........................37 SNMP ................................38 Extron Warranty ..............................39 TLP Pro 300M and TLS 300M • Contents viii...
  • Page 9: Introduction

    Both models are 3.5-inch, wall-mounted touchpanels with an 320x480 LCD touchscreen. The TLP Pro 300M works with any Extron IP Link Pro control processor and is ideal for any AV application requiring a compact touchpanel and a fully customizable interface. They mount in portrait or landscape orientation...
  • Page 10: Tlp Pro 300M Only

    • View the complete day’s reservations and availability — Allows for planning efficiency and usability. • No recurring costs or maintenance fees — Reduces administrative and operational costs, and enables predictable expenditure. TLP Pro 300M and TLS 300M • Introduction...
  • Page 11 Adjustable motion detector — Senses user presence and triggers relevant actions to activate and deactivate the panel based on user presence. • Designed for the SMB 111T Surface Mount Box — Available in black or white finish to complement any environment. TLP Pro 300M and TLS 300M • Introduction...
  • Page 12: Application Diagram

    50mA Audio Audio HDMI Audio Extron Extron 4K Media Player SM 3 TLP Pro 300M Surface Mount 3.5" Portrait Wall Speakers Mount TouchLink Pro Touchpanel Figure 1. TLP Pro 300M Application Diagram TLP Pro 300M and TLS 300M • Introduction...
  • Page 13: Tls 300M

    For a complete list of the requirements for running GUI Designer, Global Configurator Plus and Professional, Global Scripter, or Toolbelt, see the Extron Web page for the appropriate software. NOTE: The TLP Pro 300M is not compatible with Global Configurator 3 or GUI Configurator. TLS 300M...
  • Page 14: Installation Overview

    Secure Sockets Layer (SSL) security certificate. IEEE 802.1X authentication is also supported once enabled. See Secure Sockets Layer (SSL) Certificates on page 33 or IEEE 802.1X Certificates on page 33 for more information. TLP Pro 300M and TLS 300M • Installation Overview...
  • Page 15 The GUI Designer Help File, Global Configurator Help File, and Toolbelt Help File, provide step-by-step instructions and detailed information for configuring the TLP Pro 300M. The Global Configurator Help File includes an introduction to that software and sections on how to start a project and configuration.
  • Page 16: Panel Features

    Motion sensor — Detects motion between three to five feet from the touchpanel, and at least 15° from the center axis. Light sensor — Monitors ambient light level and adjusts screen brightness, based on the settings configured using the Setup Menu on page 12. TLP Pro 300M and TLS 300M • Panel Features...
  • Page 17: Rear Panel Features

    Status light • TLP Pro 300M — These LED lights can blink or remain lit steadily and they can light red or green. They can be configured (using Global Configurator) or programmed (using Global Scripter) to provide feedback information about the system using these variables. Different combinations, for example a red LED lit steadily or a green LED that is blinking, can be associated with different events to provide indications about the system.
  • Page 18: Connecting A Power Injector

    3. Connect the IEC power cord to a convenient 100 VAC to 240 VAC, 50-60 Hz power source ( ATTENTION: • The TLP Pro 300M is intended for connection to a Power over Ethernet circuit for intra-building use only and are considered to be part of a Network Environment 0 per IEC TR62101. •...
  • Page 19 The power supply shall not be permanently fixed to building structure or similar structure. • La source d’alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire. TLP Pro 300M and TLS 300M • Panel Features...
  • Page 20: Setup Menu

    When the touchpanels are powered on, the currently loaded project is displayed. The figures in this section show the TLP Pro 300M. The screens for the TLS 300M contain the same information. To access the setup menu, press the Menu button (see figure , on page 9).
  • Page 21: Status

    Audio System Volume System Mute Project Information System Project Name GUI Project Name Advanced Primary Controller Address 192.168.254.250 System ID 6661 Storage 1 / 4313 MB Figure 7. Status Screen TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 22: Network

    IP Address, Subnet Mask, Gateway and DNS Primary allow them to be edited. 2. If DHCP is on, press the arrow next to the Hostname button to edit the host name. TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 23 Network screen. Press the left arrow (<) in the heading to exit the dialog and return to the Network screen without saving changes. SUBMIT Figure 10. Address Dialog Box TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 24: Display

    Wake on Motion — Activates the panel from sleep mode when motion is detected near the unit. Toggle between On and Off. If Wake on Motion is off, touch the screen to activate the panel. TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 25: Audio

    To mute any of the volume settings, press the corresponding loudspeaker icon to toggle between mute off and mute on (see figure 13). Mute on Mute off Figure 13. Mute On and Off Icons TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 26: Project Information

    Project Information This screen only applies to the TLP Pro 300M. The TLS 300M does not have a Project Info screen. Project Info EXIT System Project Name GCPro Project.gcpro Version 1.0.2.0 Creation Date 11/12/19 10:23:04 AM Revision Date 01/18/20 12:30:00 PM...
  • Page 27: Advanced

    Professional Help File. If the TLP Pro 300M connects to the control processor, a green circle with a white check mark is shown. If the TLP Pro 300M does not connect, a red circle with a white X is shown.
  • Page 28: Linklicenses

    LinkLicenses LinkLicenses are not used by the TLS 300M. This section applies to the TLP Pro 300M only. For information about LinkLicenses LinkLicenses, see on page 32. Enable LinkLicenses 1. To enable LinkLicences, set the LinkLicense switch to on by moving the toggle switch to the right (see the image to the right).
  • Page 29 19) and enter the new PIN twice as described in steps 1-4 above. To delete the PIN, set the Menu PIN to off (see the Advanced screen on page 19). TLP Pro 300M and TLS 300M • Setup Menu...
  • Page 30: Configuration Software

    • Updating Firmware Downloading and Installing Software The TLP Pro 300M uses Toolbelt, GUI Designer, Global Configurator Plus and Professional, and ControlScript Deployment Utility can be downloaded from www.extron.com. The TLS 300M uses Toolbelt and Room Agent These software programs can be downloaded from www.extron.com.
  • Page 31 Start typing the name of the software. b. When the software you are interested in is displayed underneath, click on it. c. Information about the software is shown underneath: Figure 21. Room Agent Download Page TLP Pro 300M and TLS 300M • Configuration Software...
  • Page 32: Downloading Software From The Product Page

    (username and password) for TouchLink Pro devices. GUI Designer — (TLP Pro 300M only) Design the layout of the screen text and graphics using GUI Designer, which is a Windows-based application. You can either customize one of several existing templates or create an entirely new interface.
  • Page 33: Tlp Pro 300M Web Page

    ControlScript Programming software (optional) — (TLP Pro 300M only) An Extron-exclusive Python library (ControlScript) can be used with your choice of Controlscript programming software to program your Extron control system. Room Agent — (TLS 300M only) Used to customize the user interface, connect to calendar servers, and integrate Wayfinding devices.
  • Page 34 The default web page opens for the TLP Pro 300M (figure 24) or TLS 300M (figure 25). Figure 24. TLP Pro 300M Default Web Page The single page provides general and network information about the unit. It is read-only and cannot be used to configure the touchpanel network settings.
  • Page 35: Updating Firmware

    To update firmware, first download and run the file from the Extron website. Then use Toolbelt or the TLP Pro 300M web page to upload the file to the touchpanel. Downloading Firmware The firmware must be downloaded to a PC on the same sub-network as the TLP Pro 300M. Figure 26. Downloading Firmware 1.
  • Page 36: Updating Firmware Using The Touchpanel Web Page

    Figure 28. Firmware Download Page for TLP Pro 300M 5. (Optional) Click Release Notes ( ) for more information about the firmware. 6. Click Download ( 7. Follow the on-screen instructions to download the program. An executable file is downloaded to the PC.
  • Page 37: Mounting

    Do not install the TLP Pro 300M or TLS 300M in a fire resistant rated wall or partition assembly. • Ne pas installer le TLP Pro 300M ou le TLS 300M dans un mur résistant au feu ou une cloison. •...
  • Page 38: Mounting With A Ul-Listed Electrical Box

    6. Secure the metal mounting plate to the junction box, using the #6-32 x ¾” pan-head screws. Both the mounting plate and the screws are provided. 7. Attach cables to the back of the TLP Pro 300M (see Rear Panel Features on page 9).
  • Page 39: Mounting To Drywall Or Furniture

    Figure 31. Mounting to Drywall or Furniture in the Landscape Orientation 1. Download the TLP Pro 300M and TLS 300M Cut-out Template from www.extron.com. Ensure that it is printed at 100% size, with no scaling. 2. Remove the cut-out area from the template.
  • Page 40: Linklicenses

    For more information about Control System LinkLicenses, go to https://www.extron.com/product/linklicense. How Do Customers Obtain a LinkLicense? Customers can obtain a LinkLicense by purchasing a redemption code and applying it to the TLP Pro 300M. LinkLicenses cannot be applied to the TLS 300M 1.
  • Page 41: Reference Material

    For information about network port requirements and licensed third-party software for all the touchpanels described in this guide, please refer to the Extron Control Product Network Ports and Licenses Guide, which is available at www.extron.com. TLP Pro 300M and TLS 300M • Reference Material...
  • Page 42: Reset Modes

    Reset Modes The TLP Pro 300M touchpanel has three reset modes that are initiated by pressing the Reset button. An additional (fourth) mode toggles between enabling and disabling the DHCP client: • Use Factory Firmware (see below) • Reset Network Settings (see page 35) •...
  • Page 43: Reset Network Settings

    Full Factory Reset mode performs a complete reset to factory defaults (except the firmware). • Does everything Reset All IP Settings mode does. • Removes touchpanel user interface layout and configurations. • Resets all touchpanel settings to factory default. TLP Pro 300M and TLS 300M • Reference Material...
  • Page 44: Toggle Dhcp Client

    NOTE: ITU-T standard X.509 covers aspects of public key encryption, digital cryptography, certificates, and validation. Contact your IT administrator for more information on what tools and policies are required to obtain or create the SSL certificate and, if necessary, the corresponding passphrase. TLP Pro 300M and TLS 300M • Reference Material...
  • Page 45: Ieee 802.1X Certificates

    Some special characters (colon [:], underscore [_], and hyphen [-]) • It has a file extension that is .key or .pem. • It can have optional encryption (via password or passphrase). TLP Pro 300M and TLS 300M • Reference Material...
  • Page 46: Snmp

    Extron control products support the following security levels: • Management Information Base 2 (MIB-II) • SNMPv2c. TLP Pro 300M and TLS 300M • Reference Material...
  • Page 47: Extron Warranty

    Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.

This manual is also suitable for: