Handling
Switching
with
four-
channel control
Control
Indication
Control type
Switching with co-con­
traction
Switching back
7.5.2 Programmes without use of an electric wrist rotator
Control
Indication
Control type
Switching with co-contraction
Switching back
Control
Indication
Control type
Switching by switch activation
Switching back
Control
Indication
Control type
Switching by switch activation
Switching back
Control
Indication
Control type
Switching
24
DynamicArm
Not applicable
The elbow joint is con­
trolled using a linear con­
trol element.
DynamicArm
Linear control element
For patients with two strong muscle signals
Position control
Not applicable
The elbow joint is con­
trolled by the linear control
element.
Automatically switching back to the hand component takes place five seconds after
relaxing the muscles.
DynamicArm
Two electrodes and linear control element
For patients with two strong muscle signals
Proportional
Switching to the hand
Automatically switching back to the hand component takes place five
seconds after relaxing the muscles.
DynamicArm
Two electrodes and switch
For patients with two strong muscle signals
Proportional
Switching to the hand
Automatically switching back to the hand component takes place five
seconds after relaxing the muscles.
DynamicArm
Two switches
For patients with weak or no muscle signals
Digital
Switching to the hand
Automatically switching back to the hand component takes place five
seconds after relaxing the muscles.
DynamicArm
Linear control element
For patients with two muscle signals of any strength
Possibility for simultaneous control of elbow joint and terminal device
Position control
Electric wrist rotator
Switching with fast and
high electrode signals.
Electric wrist rotator
Two electrodes
Proportional
Switching to the terminal
device
System Electric Hand and System
Switching to the elbow joint
System Electric Hand and System
Switching to the elbow joint
System Electric Hand and System
Switching to the elbow joint
System Electric Hand and System
Two electrodes
Proportional
Switching to the elbow joint
System Electric Hand
and System Electric Gre­
ifer
Switching with slow and
low electrode signals.
System Electric Hand
and System Electric Gre­
ifer
Switching to the electric
wrist rotator
Electric Greifer
Electric Greifer
Electric Greifer