Logical Pipeline Control (From 3800H); Mechanism Control (From 3C00H) - HP LTO Ultrium Technical Reference Manual

Table of Contents

Advertisement

Code
341Ch
341Dh
341Eh
341Fh
3420h
3421h
3422h
3423h
3424h
3425h
3426h
37FFh

Logical pipeline control (from 3800h)

Error
3800h
3801h
3802h
3803h
3804h
3805h
3806h
3BFFh

Mechanism control (from 3C00h)

Error
3C00h
3C01h
104
Drive error codes
Description
Linked-list 'next' pointer is invalid.
CRAM transfer started but not finished.
Allocated insufficient CRAM.
Dataset is available in LM but the drive is not positioned to append.
Datasets in LM, Flush WITH_EOD required before the current operation
LM flushed but EOD is required before the current operation.
The specified dataset type is not supported by the operation.
The specified CRAM dataset type is not supported.
LF has attempted an operation away from EOD that can only be performed at EOD.
Search dataset available dataset number does not match the DSIT contents.
LF has requested a dataset while LM is changing to backup mode.
Undefined error.
Description
No error. Synonymous with GOOD status.
Aborted operation.
Busy. An operation request was received while in a transient state.
The value of a parameter received with a Logical Pipeline Control operation request falls
outside its valid range.
Received an operation request while in a mode that does not allow that operation.
Operation aborted because of a write-behind error.
Logical Pipeline Control has detected an unexpected File Mark during a Space operation.
A non-specific error has occurred in Logical Pipeline Control.
Description
No error.
Aborted command error.