Control Mode - HP StorageWorks 1/16 Tape SuperLoader Manual

Table of Contents

Advertisement

Installation and Configuration
3. On the Configuration submenu, scroll to SCSI ID.
Figure 17: Select SCSI ID
4. Press Enter.
5. Scroll to the number you want to set as the SuperLoader SCSI ID.
Figure 18: Set SCSI ID
6. Press Enter.
7. Reboot for the new SCSI ID to appear on the LCD.
The new SCSI ID is now in effect.

Control Mode

You can set the SuperLoader to either Sequential, Random, Mixed, or Seq Cycle
Mode. The default control mode is Random.
The Sequential mode supports certain backup applications that do not manage
media. During backup, when one cartridge is read or written to the end of the tape,
the SuperLoader automatically returns that cartridge to its slot and loads the
cartridge from the next higher numbered slot to the tape drive to be read or written
to. This continues until the backup software stops accessing the drive or until all
the cartridges have been sequentially accessed.
In Random control mode you can specify which cartridge you want to use and
where you want it to go. You will probably use this mode the most.
26
SCSI ID
Ethernet
Time
Change Mode
Cleaning Tape
to change
Enter to continue
SCSI ID: 05
a. Press and hold the power button on the front panel until Power Off
appears on the LCD.
b. Press the power button again to power on the SuperLoader.
1/16 Tape SuperLoader Reference Guide