Error
Description
5810h
Wrong number of parameters.
5820h
Could not set Prometheus 0 to default values.
5821h
Could not set Prometheus 1 to default values.
5822h
Could not set Prometheus 2 to default values.
5823h
Could not set Prometheus 3 to default values.
5824h
A valid Mod level was not received from the PCA EEPROM.
5825h
Could not set Prometheus 4 to default values.
5826h
A failure was detected during a Write Element Resistance test for Artemis.
5827h
A failure was detected during a Read Element Resistance test for Apollo.
Artemis did not achieve PLL lock. Parameter 1 is Artemis (0=BumpA, 1=BumpB, FFh=No
5828h
Artemis was specified). Parameter 2 is value of the Artemis PLL register.
5830h
Could not set Hyperion 0 to default values.
5831h
Could not set Hyperion 1 to default values.
5840h
Could not initialize the Diagnostic Data rwInitDiagnosticData.
Did not get either INTODRIVE or INTOCARTRIDGE.
5841h
5850h
Delilah failed to autocalibrate.
Gideon failed to autocalibrate: param1 = GideonRegisters, param2 = RegisterValue, param3
5851h
= nothing.
Gideon HyperTransport PLL failed to come out of reset: param1 = GideonRegisters, param2
5852h
= RegisterValue, param3 = nothing.
5853h
HyperTransport sync failure: param1 = bus, param2 = count, param3 = type.
5854h
HyperTransport parity failure: param1 = bus, param2 = count, param3 = type.
HyperTransport unexpected parity state at power-on: param1 = HT Parity Error, param2 =
5855h
HT Parity Error count 0, param3 = HT Parity Error count 1.
A valid Blo Dac Gideon Register setting could not be determined in the manual calibration
5856h
mode.
The Mech Interface firmware returned a failure to RWC firmware when requested to set an
5857h
ATS clock frequency for Gideon calibration.
The Random Bit Sequence generator failed to collect the required samples in the allowed
5858h
time.
A valid Blo Dac Gideon register setting could not be determined in the manual calibration
5859h
mode, retrying the Gideon offset calibration.
5860h
Expected a compatible data tape but got something else.
114
Drive error codes