Installer Setup - Honeywell Home T10 Pro RedLINK Manual

Smart thermostat
Hide thumbs Also See for T10 Pro RedLINK:
Table of Contents

Advertisement

Installer Setup

ISU #
Name
None
Language
None
Room
None
Room
None
Units
None
RedLINK
Devices
None
Outdoor
temperature
2000
System Type
2010
Equipment
Type
2060
Reversing Valve • O (O/B on Cool)
Table 5. Installer Setup (ISU)
Settings
• English
Engligh
• Francais
• Espanol
• Bedroom
No defaulted
• Living space
value
• Other
Bedroom:
• Guest Bedroom
• Master Bedroom
• Add room
Living Space:
• Family room
• Living Room
• Rec Room
• Add room
Other:
• Dining Room
• Kitchen
• Basement
• Hallway
• Add room
• Fahrenheit
Fahrenheit
• Celsius
• Add device
• Set up later
• None
None
• Wired
• Internet
• Conventional
Conventional
Forced Air Heat
Forced Air Heat
• Heat Pump
• Radiant Heat
• None (cool only)
Conventional Forced
Air Heat
• Standard Efficiency
Gas Forced Air
• High Efficiency Gas
forced air
• Oil Forced Air
• Electric Forced Air
• Hot water Fan Coil
Heat Pump
• Air to Air
• Geothermal
Radiant Heat
• Hot Water Radiant
Heat
• Steam
None (cool only)
O (O/B on Cool) Only displayed if the system type (ISU 2000)
• B (O/B on Heat
17
T10 PRO SMART THERMOSTAT WITH REDLINK
Default
In what type of room will this thermostat be
installed?
These questions are asked for two reasons:
1. Other RedLINK indoor sensors could
be used for other spaces in the home.
When these sensors are used, the cus-
tomer is able to select certain sensors
to have priority under certain condi-
tions (active rooms based on motion
detection, selected rooms based on
schedule settings).
2. There may be multiple thermostats in
the same location controlled via the
app.
Which temperature scale would you like to
use?
Use to connect RedLINK wireless
Accessories.
List of compatible RedLINK accessories
shown on page 4. Thermostat display will
guide you through linking RedLINK
accessories to thermostat.
Outdoor temperature is used for balance
point lockout, aux heat lockout, frost control,
high and low outdoor temperature lockouts
for ventilation
This ISU is not displayed when ISU 2000
Heating System Type is set to None (Cool
Only).
Available options depend on "System Type"
setting
Cycle Rate and Fan Operation automatically
default to the correct settings based on the
equipment type selected.
is set to Heat Pump
Notes
33-00462—01

Hide quick links:

Advertisement

Table of Contents
loading