Specifications - Honeywell Home T10 Pro RedLINK Manual

Smart thermostat
Hide thumbs Also See for T10 Pro RedLINK:
Table of Contents

Advertisement

SPECIFICATIONS

Table 1. Thermostat Description
Feature
Powering Method
Common wire required
Stages:
Equipment type:
• Up to 3H/2C
• Dual fuel
Heat pump
• Hot water, steam, or hot water coil
• Up to 2H/2C
• Gas or oil furnace
conventional
• High-efficiency or mid-efficiency
• Cool only
• Does not work on Milivolt systems
• Humidifier, Dehumidifier, or
Ventilator control
Changeover
Manual or Auto Changeover
Selectable
System Setting
Em Heat-Heat-Off-Cool-Auto
Fan Setting
Auto-On-Circ-Follow Schedule
Table 2. Electrical Ratings
Terminal
W (Heat)
W2 (Aux) Heat
E (Emergency Heat)
Y (Compressor Stage 1)
Y2 (Compressor Stage 2) 20-30 VAC
G (Fan)
O/B (Changeover)
L/A (Heat Pump Fault)
U (Hum, Dehum, or Vent) 20-30 VAC
Does not work on Milivolt systems
Power Consumption: 3VA
RedLINK Communication:
Frequency: 900 Mhz frequency range
Re-Sync Time: RedLINK devices re-establish communica-
tion within 6 minutes after AC power resumes.
Temperature Setting Range:
Heating: 40 to 90 °F (4.5 to 32 °C).
Cooling: 50 to 99 °F (10 to 37 °C).
Note: Adjustable high and low range-stop settings.
Temperature Sensor Accuracy:
± 1.5 F at 70 F (0.75 C at 21.0 C)
Humidification Setting Range:
10% to 60% RH.
Description
Voltage
Running
(50/60Hz)
Current
20-30 VAC
0.02-1.0 A
20-30 VAC
0.02-1.0 A
20-30 VAC
0.02-0.5 A
20-30 VAC
0.02-1.0 A
0.02-1.0 A
20-30 VAC
0.02-0.5 A
20-30 VAC
0.02-0.5 A
20-30 VAC
0.02-0.5 A
0.02-0.5 A
T10 PRO SMART THERMOSTAT WITH REDLINK
Dehumidification Setting Range:
40% to 80% RH.
Humidity Display Range:
0% to 99%.
Humidity Sensor Accuracy:
± 5% RH from 30% to 50% RH at 75 F.
Cool Indication:
Display floods blue and says "cooling to" when cool is on.
Heat or Em Heat Indication:
Display floods orange and says "heating to" when heat is
on.
AUX Heat Indication:
Display shows "Aux heat on" above the room temperature.
Interstage Differential:
Comfort:
The thermostat keeps the indoor temperature within 1
degree of the setpoint (droop less control). Unless
the system is dual fuel, or a droop setting is used, the
thermostat turns on stage 2 when the capacity on
stage 1 reaches 90%.
Clock Accuracy:
1 minute per month at 77 °F (25 °C). ± 2 minutes per
month over the operating ambient temperature
range.
Automatically
Fi router and registered to account.
Mounting Means:
Thermostat mounts directly on the wall in the living
space using mounting screws and anchors provided.
Can mount to a horizontal 2 x 4 in. junction box
using J-Box adaptor (included).
4-29/32
(125)
Fig. 2. Dimensions of thermostat in In. (mm).
3
updates when connected to Wi-
15/16
3-45/64 (94)
(24)
M37805
33-00462—01