T10 PRO SMART THERMOSTAT WITH REDLINK
S
L/A
A
S
O/B
Y
AUX
W2
Y2
E
G
W
C
K
R
U
Rc
U
1
G
R
C
Y
AIR HANDLER
1
COMMON REQUIRED FROM COOL TRANSFORMER (AIR-HANDLER).
Fig. 17. 2 Transformer system; hot water heat with air-
conditioning (or hot water coil).
S
S
Y
Y2
G
C
U
U
1 1
C
1
COMMON REQUIRED.
Fig. 18. Hot water boiler, heat only.
33-00462—01
2 TRANSFORMER SYSTEM
HOT WATER HEAT +
AIR-CONDITIONING (OR HOT
WATER COIL).
R/Rc SWITCH
DOWN
W
R
BOILER
M37557A
HOT WATER BOILER.
HEAT ONLY.
A
L/A
O/B
AUX
W2
E
W
K
R
Rc
R/Rc SWITCH
UP
BOILER
W (T)
R (T)
S
S
Y
Y2
G
1
C
U
U
1
COMMON REQUIRED.
Fig. 19. Hot water heat with power open zone valve.
S
S
Y
Y2
G
C
U
U
1
M37819
C
G
1
COMMON REQUIRED.
Fig. 20. 2H/2C: gas furnace.
10
HOT WATER HEAT WITH
POWER OPEN ZONE VALVE.
L/A
A
O/B
AUX
W2
E
W
K
R
Rc
R/Rc SWITCH
UP
R
24 VOLTS
C
TRANSFORMER
TH
R (T)
TR
W (T)
BOILER
HONEYWELL V8043
ZONE VALVES
2H/2C GAS FURNACE +
AIR-CONDITIONING.
A
L/A
O/B
AUX
W2
E
W
K
R
Rc
R/Rc
SWITCH UP
FURNACE
Y2
Y
W2
W
R
M37559A
M37560A