Installer Setup
ISU #
Name
9050
Dehumidifi-
cation
Equipment
Setup
9070
Dehumidifi-
cation Over-
cooling Limit
9120
System Modes
Allowing
Dehumidifi-
cation
9130
Dehumidifier
Fan Control
9140
Dehumidifier
Lockout
Table 5. Installer Setup (ISU)
Settings
• Normally open
Normally
• Normally closed
Closed
0°, 1°, 2°, 3° F
3
(0.5°, 1.0°, 1.5° C)
• Heat
• Cool
• Cool
• Off
• Off
Default varies
based on
heating/
cooling
equipment
selected
• Thermostat
Off
Controls Fan
• Equipment Controls
Fan
• Dehumidifier
Dehumidifier
Allowed when Cool
Allowed when
is Running
Cool is Running
• Dehumidifier Not
Allowed when Cool
is Running
25
T10 PRO SMART THERMOSTAT WITH REDLINK
Default
Choose an option appropriate for the type of
equipment installed.
Normally Open: U contacts will normally be
open and will close when the thermostat
calls for dehumidification.
Normally Closed: U contacts will normally be
closed and will open when the thermostat
calls for dehumidification.
This ISU is only displayed when ISU 9000
Dehumidification Equipment is set to A/C
with Low Speed Fan or A/C with High Speed
Fan.
The thermostat uses the cooling system to
reduce humidity by lowering the
temperature up to 3° F below the current
cool setpoint until the desired humidity level
is reached.
The thermostat keeps the temperature
below the cooling setpoint until the desired
humidity level is reached.
0° F is only an option when ISU 9000
Dehumidification Equipment is set to A/C
with Low Speed Fan.
This ISU is only displayed when ISU 9000
Dehumidification Equipment is set to Whole
House Dehumidifier.
Click boxes on screen to select which system
modes allow dehumidification. If a box is
NOT checked, the thermostat will NOT allow
dehumidification to operate in that mode.
Heat: Includes Heat, Emergency Heat and
Auto. If the system is in Auto mode, the
thermostat will allow dehumidification if the
last call was for heat.
Cool: Includes Cool and Auto. If the system
is in Auto mode, the thermostat will allow
dehumidification if the last call was for cool.
Off: The thermostat will allow
dehumidification when the system setting is
Off.
See "Dehumidification" on page 34.
This ISU is only displayed when ISU 9000 is
set to Whole House Dehumidifier.
Thermostat Controls Fan: The thermostat
turns on the dehumidifier and the fan when
dehumidification is needed.
Equipment Controls Fan: The thermostat
turns on the dehumidifier when
dehumidification is needed. The fan is
controlled by the equipment.
This ISU is only displayed when ISU 9000 is
set to Whole House Dehumidifier.
Dehumidifier Allowed when Cool is
Running: Dehumidifier can run when the
cooling system is on.
Dehumidifier Not Allowed when Cool is
Running: Dehumidifier can NOT run when
the cooling system is on.
Notes