Honeywell Home T10 Pro RedLINK Manual page 24

Smart thermostat
Hide thumbs Also See for T10 Pro RedLINK:
Table of Contents

Advertisement

T10 PRO SMART THERMOSTAT WITH REDLINK
Installer Setup
ISU #
Name
8050
Humidification
Window
Protection
8060
System modes
allowing
Humidification
8070
Humidification
Control
8100
Humidifier Pad
Replacement
Reminder
8100
Clean Tank/
Water Filter
9000
What Type of
Dehumidifier
Equipment Do
you Have?
33-00462—01
Table 5. Installer Setup (ISU)
Settings
• Off
Off
• On
Check box on screen
Heat
for each:
• Heat
• Off
• Humidify Only when
Defaults to
Heat is On
Humidify Only
• Humidify Only when
when Heat is
Fan is On
On when ISU
• Humidify on
8000
Demand:
Humidifier Type
Thermostat
is Bypass or Fan
Controls Fan
Powered.
• Humidify on
Defaults to
Demand: Humidifier
Humidify on
Controls Fan
Demand:
Thermostat
Controls Fan
when ISU 8000
Humidifier Type
is Steam
• Off
Off
• 60 Run Time Days
• 90 Run Time Days
• 6 Calendar Months
• 12 Calendar Months
• Off
Off
• 60 Run Time Days
• 90 Run Time Days
• 6 Calendar Months
• 12 Calendar Months
• None
None
• A/C with Low Speed
Fan
• A/C with High
Speed Fan
• Whole House
Dehumidifier
24
Default
Requires either wired outdoor sensor or
Internet weather (thermostat connected to
Wi-Fi and registered to the app).
Off: The thermostat controls the humidity
level to the user's desired humidity setting.
Frost or condensation may appear on
windows.
On: The thermostat prevents frost or
condensation on windows by not allowing
the humidity to go above the "Window Limit"
when it is controlling the humidifier. The
"Window Limit" is based on the current
outdoor temperature and the user's window
protection setting. The "Window Limit" is
displayed on the user's humidification
screen. See "Window Protection" on page 34.
Click boxes on screen to select which system
modes allow humidification. If a box is NOT
checked, the thermostat will NOT allow
humidification to operate in that mode.
Heat: Includes Heat, Emergency Heat and
Auto. If the system is in Auto mode, the
thermostat will allow humidification if the
last call was for heat.
Off: The thermostat will allow humidification
when the system setting is Off.
See "Set up Humidification" on page 34.
Humidify Only when Heat is On: The
thermostat turns on the humidifier only if
the heat is currently running.
Humidify Only when Fan is On: The
thermostat turns on the humidifier only if
the fan is currently running.
Humidify on Demand - Thermostat Controls
Fan: The thermostat turns on the humidifier
and the fan when humidification is needed.
Humidify on Demand - Humidifier Controls
Fan: The thermostat turns on the humidifier
when humidification is needed and the
humidifier controls the fan.
This ISU is only displayed if ISU 8000
Humidifier Type is Bypass or Fan Powered or
none. Run Time Days are not shown if ISU
8000 Humidifier Type is set to None
This ISU is only displayed if ISU 8000
Humidifier Type is Steam.
See "Dehumidification" on page 34.
Whole House Dehumidification and A/C
with Low speed Fan only available if not
configured to control a Humidifier or
Ventilator. A/C with low Speed Fan requires
equipment that has a terminal
to lower fan speed.