Replacing The Manifold Block, Supply Plate Or Mpa−F End Plate - Festo MPA-F Series Description Pneumatics

Valve terminal
Hide thumbs Also See for MPA-F Series:
Table of Contents

Advertisement

5. Conversion and maintenance
Mounting
5.3.5 Replacing the manifold block, supply plate or MPA−F end plate
Dismantling
Festo P.BE−MPAF−EN en 0804NH
Proceed as follows:
Caution
Replace an electronics module only by an electronics mod
ule of the same type.
You can then avoid problems in controlling the solenoid
coils and damage to the electrical contacts.
Note
Before mounting, check the condition and position of the
following seals:
The seals of the electronics module
The ring seal of the electrical contacts
The cord seal of the valve or cover plate
1. Place the electronics module in the manifold block
2. Tighten the screws of the electronics module to 0.4 Nm
(±20%).
3. Then mount the valves or cover plates (see section 5.3.3).
Proceed as follows:
1. Loosen the electrical and pneumatic connections and re
move the MPA−F valve terminal from its fastening surface
(see section 5.2).
2. Place the MPA−F valve terminal on a flat working surface.