Characteristics - Siemens SIPROTEC 6MU805 User Manual

Merging unit
Table of Contents

Advertisement

1.3

Characteristics

General Properties
• Powerful 32-bit microprocessor system
• Complete digital processing and control of measured value, from the sampling and digitalization of the mea-
sured quantities to close and trip decisions for the switchgear component
• Complete galvanic and interference-free isolation of the internal processing circuits of the measurement,
control and supply circuits of the system using instrument transformers, binary input and output modules,
and DC and AC voltage converters
• Easy device operation using the Web Monitor or a connected PC running DIGSI
• Continuous calculation and displaying of measured values and count values
• Continuous monitoring of the measured quantities and of the device hardware and software
• Communication with protection device and data storage equipment
• Battery-buffered clock which can be synchronized via a synchronization signal via GPS, IRIG-B or SNTP
(Simple Network Time Protocol) via Ethernet interface
• Operating hours counter: Counting the operating hours of the protected object under load
• Commissioning aids such as connection and direction check, status indication of all binary inputs and out-
puts, easy testing of port F, and influencing of information at port F during test operation
• Replacement of conventional wiring between primary and secondary devices through optical cables
• Support point to point. Using of redundant network technology (PRP, HSR)
• Use of proven SIPROTEC / DIGSI4 technology
• Easy installation and configuration supported by DIGSI and Syscon (System Configurator) via USB interface
Special Properties of Merging Unit
• Acquisition of 4 currents (1 A, 5 A) and 4 voltages (100 V, 110 V) of conventional current and voltage instru-
ment transformers of power system data
• Accurate synchronization of the acquisition by PPS/IRIG-B or GPS signals
• Publishing sample values fully compatible with IEC 61850-9-2
• Accurate data transmission via fiber optics, no EMC disturbance on the communication
• Transmission and receiving of GOOSE messages according to IEC 61850 standard
• Optional support of redundancy technology HSR and PRP according to IEC 62439-3
• Commissioning support by operational measurements and SV records
- Proven at a temperature range of -40 °C to +85 °C
- Optional HMI with display, LEDs and keypad
• Configuration together with SIPROTEC 5 with IEC 61850-9-2 interfaces
Device Operation
• Device operation via the Web Monitor
• Operation via operation panel. The operation panel can also be mounted detached from the device.
SIPROTEC, 6MU805, Manual
C53000-G1140-C380-5, Release date 06.2018
Introduction
1.3 Characteristics
13

Advertisement

Table of Contents
loading

Table of Contents