– The ISDN time synchronization and NTP service must be activated
simultaneously.
Ascotel® IntelliGate® Net:
In an AIN there are additional configuration parameters for time synchro-
nization between the nodes.
The Master is always in AIN area 1. This area is always assigned the Master
time. Time differences with other nodes can now be configured based on
the Master time.
Example: Master is in Switzerland; satellite is in Finland. The time differ-
ence with UTC is: CH +01:00, FI +02:00.
Entry for the Master:
Entry for the satellite: Time zone shift: +01:00
If the time is synchronized via an NTP server the parameter
ence with UTC (+/- hh:mm)
ter time differs from UTC by 1 hour.
System configuration
Tab. 334 System time and system date: System configuration
Parameter
System time
system date
Automatic changeover to sum-
mer time
Time difference with UTC (+/-
hh:mm)
NTP service
NTP Server
ISDN time synchronisation
Master time
Time zone shift
Reference to Other Features
Features:
"Appointment call", page 433
"Time-controlled functions", page 486
"Remote controlling features from outside the system", page 483
Features
System Functions and Features as of I7.9
Time zone
shift: 00:00
must also be configured to +01.00 as the Mas-
Parameter value
<hh:mm:ss>
<dd.mm.yyyy>
Yes
/
No
Yes
/
No
Yes
/
No
<Address or name>
Yes
/
No
Yes
/
No
<±hh:mm>
Legend / Remarks /
Invalid times are not accepted
Possible data: 01.01.1980...31.12.2999
The time change is synchronized throughout the
European Union and in many other countries
In an AIN depending on the Master's location
If name is entered, configure DNS settings
Usually assigned to only one AIN region
Information field. Always in the AIN Region 1 in
which the Master is also located.
±12 hours in steps of 15 minutes