Chapter 5
Install the Center Rack Control
Machine's Center Boom Function Coils
FIGURE 15.
Locate the center up coil on the machine's stack valve.
1.
Unplug the coil connector from the center up coil.
2.
Install a center rack control boom sense adapter cable (P/N 115-0230-039) to the machine's Up coil.
3.
Connect the coil connector to the installed boom sense adapter cable.
4.
Plug the single connectors on the installed boom sense adapter cable in the Center Up harness connectors
5.
on the AutoBoom valve harness (P/N 115-0230-045 or 115-0230-085).
Locate the center down coil on the machine's stack valve.
6.
Unplug the coil connector from the center down coil.
7.
Install a center rack control boom sense adapter cable (P/N 115-0230-039) to the machine's Down coil.
8.
Connect the coil connector to the installed boom sense adapter cable.
9.
Plug the single connectors on the installed boom sense adapter cable in the Center Down harness
10.
connectors on the AutoBoom valve harness (P/N 115-0230-045 or 115-0230-085).
Open Center Dump Valve Coil
FIGURE 16.
Locate the open center dump valve coil on the machine's hydraulic valve.
11.
Unplug the coil connector from the open center dump valve coil.
12.
Install a boom sense adapter cable (P/N 115-0171-546) on the coil.
13.
56
Flexi-Coil 2007 68 Series, CaseIH SRX Series, & New Holland 216 - 120'-134' Booms