Chapter 5
Install the UltraGlide Wiring
Wiring Connections
For wiring connections made outside of the cab, apply dielectric silicone grease (P/N 222-0000-006)
generously on both the male and female ends of the connectors. Application of the grease will prevent
corrosion to the pins and wires.
Install the AutoBoom Node
UltraGlide AutoBoom Node Installed
FIGURE 13.
Mount the AutoBoom node (P/N 063-0130-013) to the AutoBoom valve mounting plate (P/N 107-0171-802)
1.
using three 3/8"-16 zinc hex bolts (P/N 311-0054-106) and three 3/8"-16 zinc flanged lock nuts (P/N 312-
1001-164).
Note:
Make sure that the node is positioned so that the cable connectors face down or to the side.
Insert the large, rectangular node connectors on the harness cable (P/N 115-0230-045 or 115-0230-085)
2.
into the correct ports of the AutoBoom valve.
Tighten the bolts on the node connectors to secure the connections.
3.
Connect the Harness Cable to the Boom Function Controls
Locate the Left Press and Right Press connectors on the harness cable (P/N 115-0230-045 or 115-0230-
1.
085).
Route the connectors to the AutoBoom valve (P/N 063-0131-126).
2.
Connect the Left Press connector to Port G1 on the AutoBoom valve.
3.
54
Flexi-Coil 2007 68 Series, CaseIH SRX Series, & New Holland 216 - 120'-134' Booms
CAUTION
Always connect the power cable as the last
step in the wiring process and verify that the
power leads are connected with the correct
polarity. Reversing power leads can cause
severe damage to the equipment.