Operating Parameters - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Technical specifications
Customer ports
Size
1)
DN19 typ 1
Axial and radial
2)
Case drain ports
7
0.875 [
Axial gauge
2)3)
ports
Radial gauge
2)3)
port
1)
Split flange Boss per ISO6162, 40 MPa series
2)
SAE O-ring boss
3)
Countersink may be deeper that specified in the standard.

Operating Parameters

14 |
©
Danfoss | August 2018
060
080
DN25 typ 1
7
0.875 [
]–14UN-2B
8
]–14UN-2B
8
Output Speed
Output Speed
Displacement
Maximum 32°
Rated
Minimum 6°
Zero 0°
Maximum 32°
Maximum
Minimum 6°
Zero 0°
System and Case Pressure, Ambient Temperature
Parameter
System pressure
Case pressure
3)
Ambient temperature
1)
Minimum above case pressure (open and closed circuit)
2)
See the graphs
Required inlet pressure diagrams (for cylinder block filling)
3)
Air temperature close to the unit.
110
160
DN25 typ 1
DN32 typ 1
1
1.0625 [1
]–12UN-2B
16
1
1.0625 [1
]–12UN-2B
16
9
0.5625 [
]–18UNF-2B
16
Unit
060
080
3600
3200
5900
5300
6600
5950
-1
min
(rpm)
4500
4100
7250
6600
7950
7200
Maximum working
Maximum
1)
Minimum
Rated
Maximum
Minimum
Maximum
Minimum
210
DN32 typ 1
DN32 typ 1
5
1.313 [1
]–12UN-2B]
16
Size
110
160
210
2900
2600
2350
4800
4250
3850
5350
4750
4300
3700
3300
3000
5950
5250
4800
6500
5750
5250
All sizes
450 bar [6527 psi]
480 bar [6962 psi]
2)
3 bar [44 psi]
5 bar [73 psi]
0.3 bar [4 psi]
70 °C [158 °F]
-40 °C [-40 °F]
on page 16.
AX00000025en-US0504
250
250
2200
3650
4050
2800
4500
4900

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110

Table of Contents