H1F Operating Parameters; H1F Required Inlet Pressure Table (For Cylinder Block Filling) - Danfoss H1F 060 Service Manual

Bent axis fixed displacement motor
Table of Contents

Advertisement

Service Manual
H1F Bent Axis Fixed Displacement Motors, Size 060/080/110/160/210/250
Technical specifications

H1F Operating Parameters

H1F Required inlet pressure table (for cylinder block filling)

©
Danfoss | April 2024
Customer ports
Configuration Size
1)
Axial and radial
2)
L1, L2
3)
Bleed port
1)
Split flange Boss per ISO6162, 40 MPa series
2)
Metric O-ring boss
3)
Countersink may be deeper that specified in the standard.
Output Speed
Output Speed
Rated
Maximum
System and Case Pressure, Ambient Temperature
Parameter
System pressure
Case pressure
1)
Ambient temperature
1)
Air temperature close to the unit.
60cc / 80cc
Speed (RPM)
900
1400
2100
2800
3200
4000
This pressure ensures that the cylinder block will be properly filled and that there is no pulling between
piston and shaft.
The required pressure is 0 bar at 0 rpm and increases with rpm.
060
DN19 typ 1
M22x1,5
M14x1,5
Displacement
Maximum 32°
Maximum 32°
Maximum working delta
Maximum working abs
Max delta
Max abs
Min low loop
Rated
Maximum
Minimum
Maximum
Minimum
Pressure (Bar)
2
5
10
15
20
30
080
DN25 typ 1
M22x1,5
M14x1,5
Size
Unit
060
5000
-1
min
(rpm)
5500
All sizes
450 bar [6527 psi]
480 bar [6962 psi]
480 bar [6962 psi]
510 bar [7397 psi]
7.5 bar [109 psi]
3 bar [44 psi]
5 bar [73 psi]
0.3 bar [4 psi]
70 °C [158 °F]
-40 °C [-40 °F]
AX465363259664en-000201 | 11
080
4500
5000

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1f 080H1f 110H1f 160H1f 210H1f 250

Table of Contents