STORAGE
DURING STORAGE
l
Operate the engine and move the
machine
for
a short
distance
once a month so that new oil film
will
be
coated
over
movable
parts and component
surfaces.
l
Before
operating
the
work
equipment,
wipe off the grease
on the hydraulic piston rod.
A
If it is unavoidably
necessary
to carry out rust-preventive
op-
eration
while
the
machine
is
indoors, open up doors and win-
dows to improve
vetilation
and
prevent the gas poisoning.
AFTER STORAGE
After
storage
(when
it is kept
without
cover or the rust-preventive
operation
once
a
month
is
not
made), you shall apply the following
treatment
before operation.
l
Wipe
off the grease
on the hy-
draulic piston rod.
l
Loosen the drain plugs on oil pan
and other
cases and drain mixed
water.
l
You should request Komatsu
dis-
tributor
for following
service.
o Remove
the
cylinder
head
cover and lubricate
sufficiently
valves
and rocker
arms. And
inspect the valve operation.
o Remove
the oil pipe flange
on
the turbocharger
oil inlet,
fill
with 0.5 to 1 I! engine oil, and
leave
the
flange
lightly
loosened.
Then,
rotate
the
engine
by the starting
motor
without
fuel
injection
and
decompression
so that the dis-
charge
of
oil
is confirmed.
Then,
tighten
the flange
and
start the engine.
l
After
the engine is started,
oper-
ate
it
until
it
is
warmed
up
completely.
- 30 -