In this display, you can invert the {Shutter Order} or rotate the order using the arrow buttons.
After you have created the order needed, press {Apply} for your changes to take effect.
Invert Rack
An {Invert Rack} option is available in Patch>Attributes>Scrollers/Wheels. This option will only
display when a fixture with a shutter frame assembly parameter is selected.
The shutter frame assembly parameter allows for the shutter assembly to be turned. When
{Invert Rack} is disabled, a encoder will move the frame assembly from the right. When enabled,
the frame assembly will move from the left.

Settings in Patch

Softkeys available for use while in patch include {Patch}, {Attributes}, and {Database}. Pressing
any of these softkeys opens a paged view of the patch display and redraws the CIA to an
expanded view of fields related to the selected page.
When creating and editing your patch, page through each of these softkeys individually to enter
more specific data about your selected device.
{Patch} Display and Settings
With patch open, Element defaults to this display. It provides access to data input fields that you
may use to define devices in your lighting system.
Note:
The Artnet and sACN offset will display here.
{Channel} - In the patch display, all channels are displayed in numerical order. When
multiple devices are patched to the same channel, the channel number is only displayed in
the first row, additional devices are indicated with part extensions (example P2) on the
next row of the table.