[Record Only] <Cue> [Next] [Enter] - stores only the manually set values into the next cue
in the list.
[Record Only] [Cue] [3] [Enter] - stores only the manually set data into cue 3.
As with [Record], filters can further restrict stored data if deployed when using [Record Only].
See
About Filters (on page 250)
Record and Record Only [+]
[+] can be used to specify a range of cues when using [Record] and [Record Only].
Note:
If no cue number is entered before the [+], the current active cue will be used.
Example:
To record only cues 5, 10, and 15:
[Record] <Cue> [5] [+] [1][0] [+] [1][5] <CueOnly/Track> [Enter]
To update the current cue and cue 7:
[Record Only] [+] <Cue>[7] <CueOnly/Track> [Enter]

Using [Cue Only / Track]

Note:
For a more detailed summary of Cue Only and Tracking modes, please see
Tracking vs. Cue Only (on
In Track Mode
When you create a new cue, any channel parameter data from the previous cue is tracked into
the new specified cue. Any changes in this new cue will also track forward into subsequent cues
until a move instruction is encountered. The [Q Only/Track] key is an exception to this behavior.
When you record a cue in the middle of an existing cue list, using the [Q Only] button will
prohibit new information from tracking into the subsequent cue. When you rerecord or update a
cue, the modifications will not track forward.
Note:
In the following examples, the command [Q Only] indicates the same key hit of
[Q Only/Track] which is a single button on the keypad. The system setting determines
the actual context of the button depending on the mode in which the system is
operating. For clarity, only the contextual function of the button is used in the
examples.
With system set to Track
[Record] <Cue> [5] [Q Only] [Enter] - records cue 5. New values or changes will not track
into the subsequent cue.
[-] [Color] [Record] <Cue> [5] [Q Only] [Enter] - as above the recorded data will not track
forward and all color data is excluded from the record operation.
[Record Only] <Cue> [5] [Q Only] [Enter] - records all manual data, but doesn't allow it to
track into subsequent cues.
[-] [5] [Record] <Cue> [6] [Q Only] [Enter] - records the specified cue, except the
contributions from channel 5. The stored data will not track forward in the list.
Double pressing [Record] will post Record Only to the command line.