Settings Descriptions
Setting
Description
Active Settings
Contains the current active settings. The scan engine operates according to these
settings. Active Settings include settings loaded from another areas, as well as new
settings added through serial commands or menu labels.
Active Settings resides in RAM, so they are lost after a power cycle.
Startup Settings
When the scan engine is powered up, data in Startup Settings is loaded to Active
Settings in RAM.
Startup Settings is in non-volatile memory.
Custom Settings
When the [BAP command is sent to the scan engine, data in Custom Settings is
loaded to Active Settings in RAM.
Custom Settings is in non-volatile memory.
Note: When reading or sending the [BAQ command, Custom Settings is overwritten
with the current Active Settings.
Factory Default
Factory Default Settings are the default settings for the scan engine. When the
Settings
default command (U2) is read or sent, these settings are loaded to Active Settings.
You can modify Factory Default Settings through Custom Command Line Settings.
For more information, see
Settings" on page
Factory Default Settings is in non-volatile memory.
3.2.1

Factory Default Settings

To return Active Settings to Factory Default Settings, set the command that corresponds to the
interface being used.
Command
Interface
U2
UART
[C01
USB-COM
SU
USB-HID
3.2.2

Save Settings

To save Active Settings to Startup Settings, send the Z2 command at the end of the command
packet you want to save.
Command
Description
Z2
Save Active Settings as Startup Settings.
*
Saving settings over 100,000 times may destroy memory. If you need to configure these settings
frequently, avoid saving every time.
Some options, like baud rate settings, may not be enabled until "Save Settings" is sent.
*
10
"How to Permanently Change the Factory Default
11.
Description
Set to UART Factory Default Settings.
Set to USB-COM Factory Default Settings.
Set to USB-HID Factory Default Settings.
Notes
Command only