11.3. Default Settings 2: Read Options, Trigger, Buzzer

Item
Setting the number of characters
Read mode
Multiple label read (1D barcode only)
NW-7 intercharacter gap check
Read time
Buzzer duration
Buzzer tone
Buzzer loudness
Buzzer transmission
Good read LED (blue)
11.4. Default Settings 3: Serial Communication Settings—RS-232C
Default Settings 3A: Serial Communication Settings—RS-232C
11.4.1.
ACK/NAK timeout
Command header
Command terminator
ACK/NAK for RS-232C comm.
Default Settings 3B: Serial Communication Settings—RS-232C
11.4.2.
Fixed length OFF all codes
Single read
Disable
1 times the number of characters
2 seconds
50 ms
Single tone (3 kHz)
Volume 1 (Maximum)
Before transmission
200 ms duration
Parameter
"U2" and "C01" Default Setting
ACK/NAK
CS time out
Parameter
Baud rate
Parity bits
Data length
Stop bits
39
Default Setting
ACK/NAK NO RESPONSE
Indefinitely
1 s
ESC/STX
CR/ETX
Disable
"U2" Default Setting
9600 bps
No parity
8 bits
1 bit
Opticon